Fire & Safety Alarm System

GE FireWorX

This collection offers a wealth of product literature on FireworX brand fire detection products from GE Security. Find material on powerful life safety systems, innovative signals and detectors, and cost-effective solutions that provide valuable features for small and mid-sized applications.

Description

Specification

1) 4/8/16 Style B (Class B) Initiating Device Circuits (IDCs). - All zones accept two-wire smoke detectors and any normally-open contact devices. - Zones 1 4/8/16 configured as general alarm zones. 2) All circuits are power-limited and supervised, meeting the latest ULC requirements using fuseless technology. 3) Two built-in, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs). 4) NACs may be programmed: - Silenceable - Non-Silenceable - Auto-Silence (program 5 to 20 minutes) 5) 1.25 AMPS of NAC power 6) 3.0 AMPS of total system power 7) Alarm, Trouble and Supervisory, Form-C relays standard. 8) 24-volt operation 9) Resettable four-wire smoke detector power @ 500 mA 10) Non-resettable power @ 500 mA 11) Integral battery charger capable of charging up to 18 AH batteries (batteries over 4 AH require use of the external battery backbox, or ULC listed equivalent). 12) One-man walk-test programmable for silent or audible test 13) Disable/Enable control per IDC 14) Reverse polarity protection 15) Control buttons: - Mode - Test - ACK (Acknowledge) Alarm Silence - Reset 16) Meet UL864, EN-54 standard. 17) LED indicators: - Earth Fault (on circuit board) - Battery Fault (on circuit board) - Charger Fault (on circuit board) Specifications AC Power: AC220V± 10% 50Hz, 2.0 AMPS, minimum 14 AWG wire (2.0 mm² ) with 600-volt insulation. Battery: Sealed lead-acid batteries only, Maximum charging circuit: 27.6VDC @ 0.8 AMP for normal flat charge, Maximum battery charger capacity: 18AH battery NOTE: Two 4AH batteries can be housed in the cabinet. Uire separate & nbp battery box. Total 24 V system power: 3.0 AMPS Notification appliance (signal) power: 2.5 AMPS Maximum current per NAC: 1.25 AMPS (expandable to 2.5 AMPS) Auxiliary Outputs: - Resettable four-wire smoke detector power @ 500 mA - Non-resettable power @ 500 mA - Integral Form-C Alarm, Trouble and Supervisory relays, rated at: 2.0 AMPS @ 30 VDC (resistive), 2.0 AMPS @ 30 VAC (resistive). NOTE: Total current for auxiliary power outputs and two NACs must not exceed 3.0 AMPS. Using Environment: Temperature: 10° C~+50° C Related Humidity: ≤ 95% (40± 2° C)


Looking for a quality and affordable price?

<